What was found
(CAN) NR 2 HYD ISO VALVE CAUTION IN FLIGHT. BECAUSE OF VERY LOW PR. & QTY IN HYD SYS NR 2, MANUAL EXTENSION OF L/G WAS C/O IAW QRH, WHEN NR 2 HYD SYS ISOLATION VALVE CAUTION LIGHT IN FLIGHT. FOUND NR 1 MLG RETRACTION ACTUATOR LEAKING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) NR 2 HYD ISO VALVE CAUTION IN FLIGHT. BECAUSE OF VERY LOW PR. & QTY IN HYD SYS NR 2, MANUAL EXTENSION OF L/G WAS C/O IAW QRH, WHEN NR 2 HYD SYS ISOLATION VALVE CAUTION LIGHT IN FLIGHT. FOUND NR 1 MLG RETRACTION ACTUATOR LEAKING.