Service difficulty report · Check Valve · Airbus A320211

Difficulty date
May 4, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Airbus A320211
Aircraft time
60,811 hours
Engine
Cfmint CFM565A1
Part
Check Valve
Part number
374612
Condition
Leaking
Location
Hyd System
Stage of operation
NR
How discovered
9
Nature of condition
K
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ACFT SUSTAINED A LEAK IN THE YELLOW HYD SYSTEM. DUE TO LOW LEVEL OF HYD FLUID, CREW SHUTDOWN PUMP RENDERING YELLOW HYD SYSTEM UNSERVICEABLE. CRF WAS REQUESTED FOR LANDING, FLIGHT DID NOT DECLARE AN EMERGENCY. YELLOW HP MANIFOLD CHECK VALVE LEAKING, CHECK VALVE, 3058GM REPLACED IAW 29-13-14-400-001-A. NO FURTHER LEAKS, FLUID ADDED TO CORRECT QTY.