(CAN) DURING A TRAINING FLIGHT, THE NR 1 FORWARD BOOST PUMP FAILED, AND THE PILOT NOTIFIED MAINTENANCE, ABOUT THIS FAULT. IT WAS FOUND THE NR 1 FWD BOOST PUMP NOISE FILTER PN A.3210 HAD SHORTED OUT AND NR 2 PUMP NOISE FILTER CONNECTION WAS ABOUT TO FAIL. THIS ACFT HAD ACUMINATED, TAT: 141.2 HRS SINCE NEW AND HAD RECENTLY BEEN RECONFIGURE TO OPERATE ON WIPAIRE AMPH FLOATS, AND HAD FLOWN ONLY 10 HRS SALTWATER. THE FAILED UNITS WERE REPLACED AND CORROSION PREVENTIVE MEASURE WERE TAKEN, AND THE ACFT WAS THEN RETURNED TO SERVICE. THERE WAS AN MRO FINDING GENERATED AND GIVEN TO MFG TECH SUPPORT FOR THEIR INVESTIGATION.