Service difficulty report · Seal · Emb ERJ190100IGW

Difficulty date
June 4, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
19,879 hours
Engine
Ge CF3410E5A1
Part
Seal
Condition
Failed
Location
Pre-Cooler
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON CLIMB OUT RECEIVED BLEED 2 MESSAGE,BLEED 1 ALREADY ON MEL,DESCENDED FROM FL250, CABIN PRESSURE RETURNED TO NORMAL.AIR RETURN, NO EMERGENCY DESCENT,NO EMERGENCY DECLARED WITH ATC,NOT OVERWEIGHT FOR LANDING. DUE TO CAS MSG BLEED 2 LEAK AT LOCATION 14.7 IN CH1 & 16.4 IN CH2, CARRY OUT INSPECTION OF THE RT PRE-COOLER EXHAUST DUCT SEAL, FOR SIGNS OF DETERIORATION OR DETACHMENT FROM THE PYLON EXHAUST DUCT AS PER AMM TASK 36-11-08-210-801-A. PRE-COOLER EXHAUST DUCT SEAL REPLACED AS PER AMM 36-11-08.