Service difficulty report · Flap System · Emb ERJ190100IGW

Difficulty date
June 18, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
19,506 hours
Engine
Ge CF3410E5A1
Part
Flap System
Condition
Out Of Rig
Location
Te Flaps
Stage of operation
TX
How discovered
O
Nature of condition
W
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LEFT INBD LOWER ROD ON NR 1 FLAP TRACK FOUND BENT ON ARRIVAL. AFTER MECHANICAL RIGGING COMPLETED FOUND INBD FLAP MECHANISM UPPER AND LOWER RODS AND FLAP MECHANISM NR 2 UPPER AND LOWER RODS NOT PROPERLY ADJUSTED. MECHANICAL RIGGING OF LT AFT FLAP, FLAP TRACK 1 & 2, C/OUT IAW AMM 27-50-00-820-801-A, CHECKS SERVICEABLE. FOUND INBD FLAP MECHANISM NR 1 & NR 2 UPPER AND LOWER RODS ADJUSTED INCORRECTLY. REPLACED INBD LOWER FLAP MECHANISM ROD IAW AMM 57-54-30-400-801-B. ADJUSTED LT INBD FLAP MECHANISM NR 1 & NR 2 UPPER AND LOWER ROD IAW AMM 57-54-30-400-801-B. OPS TEST C/OUT SERVICEABLE IAW AMM 27-50-00-710-801-A/400.