Service difficulty report · Tube · Emb ERJ190100IGW

Difficulty date
November 7, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
19,197 hours
Engine
Ge CF3410E5A1
Part
Tube
Part number
19005172401
Condition
Failed
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING CRUISE, THE CREW RECEIVED A SYS 2 LOW HYDRAULIC FLUID INDICATION. THE LEAK CONTINUED FOR 30 MINUTES UNTIL THE SYS WAS EMPTY AND THE PUMP FAILED. THE QRH WAS CARRIED OUT AND A PAN WAS DECLARED WITH ATC. THE FLIGHT LANDED WITHOUT FURTHER EVENT WITH THE CREW ABLE TO USE DIFFERENTIAL BREAKING TO EXIT THE RUNWAY AND TAXI TO THE RAMP. THERE WAS NO ADVERSE PASSENGER REACTION. THE DUTY PILOT AND FLIGHT SAFETY WERE ADVISED. RESOLUTION HYD SYS NR 2 TUBE ASSY. REPAIRED IAW AMM 20-10-03-300-801-A, WP AC017756. LEAK AND FUNCTION CHECKS CARRIED OUT NO FAULTS.