Service difficulty report · Controller · Emb ERJ190100IGW

Difficulty date
November 7, 2013
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
20,564 hours
Engine
Ge CF3410E5A1
Part
Controller
Part number
1700064F
Condition
Failed
Location
Flaps
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ENROUTE FLIGHT EXPERIENCED A "FLAP FAIL" ECAM MESSAGE. QRH WAS CARRIED OUT AND ATC WAS ADVISED WITH A PAN DECLARED. THE ACFT LANDED WITHOUT FURTHER INCIDENT. THE ACFT STOPPED ON THE RUNWAY FOR EMERGENCY RESPONSE SERVICES TO INSPECT THE ACFT BEFORE TAXIING TO THE GATE. NO ADVERSE PASSENGER REACTION WAS REPORTED. THE DUTY PILOT AND MAINTENANCE CONTROL WERE ADVISED. RESLOLUTION FOUND LT POSITION SENSOR RESOLVER OUT OF RANGE, LT RESOLVER 0.11, RT 0.00 SHOULD BE BETWEEN 0.05-0.05 CARRIED OUT FLAP CONTROL ELECTRICAL RIGGING IAW AMM 27-50-00, SUBTASK 820-016-A. ALL VALUES WITHIN LIMITS. BECAUSE OF FHDB REPLACED SF-ACE 1 IAW AMM 27-53-02. TESTED SERVICABLE.