What was found
(CAN) ENGINE MFG ASSY AND TEST, FOUND 2 PREFORMED PACKINGS, PN ST 6166-015 WITH SURFACE DEFECTS, LACK OF MATERIAL, AND VOIDS. OUR STOCK WAS FROZEN AND INSPECTED. ADDITIONAL PACKINGS WERE FOUND IN A SIMILAR CONDITION. THE SUPPLIER WAS CONTACTED AND FOLLOWING AN INVESTIGATION IT WAS DETERMINED THAT THE MOULD WAS RESPONSIBLE FOR THESE VISUAL DEFECTS AND LACK OF MATERIAL ON 3 LOTS OF PARTS. THEIR PREVIOUS PROCESS REQUIRED ONLY A HUMAN VISUAL INSPECTION. OUR CUSTOMERS WERE CONTACTED TO RETURN ANY UNINSTALLED STOCK FOR INSPECTION AT MFG. THE SUPPLIER HAS MODIFIED THEIR PROCESS TO REQUIRE 100 PERCENT INSPECTION BY A BASLER MACHINE.