Service difficulty report · Pump · Airbus A319114

Difficulty date
February 19, 2014
Submitted
September 14, 2015
Operation
General aviation
Make and model
Airbus A319114
Aircraft time
48,614 hours
Engine
Cfmint CFM565A5
Part
Pump
Part number
3031863001
Condition
Failed
Location
Hydraulic Sys
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THE ACFT ENCOUNTERED A GREEN HYDRAULIC FAILURE. IN CONSULTATION WITH MAINTENENCE AND FLIGHT DISPATCH, THE FLIGHT CREW ELECTED TO DIVERT. THE FLIGHT CREW DID DECLARE A PAN PAN AS A PRECAUTION FOR INITIAL PRIORITY. THE ACFT WAS LANDED OTHERWISE ROUTINELY ON RUNWAY, WHICH WAS UTILIZED TO BE CLEAR OF THE TRAFFIC ON THE ACTIVE RUNWAY 35L. THE ACFT WAS MET BY CFR AS A PRECAUTION. AFTER A BRIEF INSPECTION, THE ACFT WAS TOWED TO THE GATE. REPLACED PRESSURE SENSOR LINE FOR NR 1 ENGINE HYDRAULIC PUMP. REPLACED NR 1 ENG HYD PUMP IAW AMM 29-11-51-401. LEAK CHECK CARRIED OUT.