Service difficulty report · Sensor · Emb ERJ190100IGW

Difficulty date
March 21, 2014
Submitted
September 14, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
18,249 hours
Engine
Ge CF3410E5A1
Part
Sensor
Part number
5913840
Condition
Failed
Location
Te Flap
Stage of operation
DE
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AS A RESULT OF NUMEROUS INDICATIONS, MOSTLY CONCERNING A FLAP FAILURE, THE CREW DECLARED AN EMER, RESULTING IN THE EMER VEHICLES MEETING THE FLIGHT ON ARRIVAL. DUTY PILOT, FLIGHT SAFETY & MTC CONTROL ADVISED. CHANGED LT FLAP POSITION SENSOR IAW AMM 27-53-04.