Service difficulty report · Pump · Bombdr BD1001A10

Difficulty date
March 20, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Pump
Part number
TBD
Condition
Inoperative
Location
Apu
Stage of operation
AP
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU CONTINUED TO RUN IN FLIGHT WITH THE APU MASTER SWITCH IN THE OFF POSITION. PILOT TURNED OFF APU IN FLIGHT AND THE SYNOPTIC INDICATIONS STAYED ON, TOOK A COUPLE TRIES TO GET IT OFF BUT THE SYNOPTICS STAYED ON. ON GROUND, REPRODUCED WHEN APU SELECTED OFF, THE START LEGEND CAME ON AND TRIED TO START. ISSUE IS HAPPENING ONLY WHEN CIRCUIT BREAKERS CBP2-A10 AND CBP2-A9 ARE PULLED. THOSE CBS WERE PULLED TO RELEASE THE ACFT, RT FUEL BOOST PUMP INOPERATIVE. WHEN THOSE CB`S ARE PUSHED IN, NO ISSUE. APU OPERATE THE NORMAL WAY. ISSUE UNDER INVESTIGATION.