What was found
(CAN) T/E FLAP SYS STALLING AND LOCKOUT TROUBLESHOOTING CARRIED OUT. T/E FLAP ASSEMBLIES INCLUDING TRACKS AND ROLLERS INSPECTED FOR DAMAGE, NO FAULTS FOUND. FLAP POSITION INDICATOR REPLACED AND ACFT RELEASED PENDING SATISFACTORY TEST FLIGHT. TEST FLIGHT CARRIED OUT, CREW REPORTED RT INDICATOR NEEDLE LAGS INTERMITTENTLY. SECOND FLAP POSITION INDICATOR INSTALLED AND FUNCTIONED CHECKED. ACFT RELEASED PENDING SATISFACTORY TEST FLIGHT. TEST FLIGHT CARRIED OUT, FLAPS INDICATED AND OPERATED NORMALLY. ACFT RELEASED TO SERVICE.