Service difficulty report · Switch · Cndair CL600*

Difficulty date
April 8, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Cndair CL600*
Aircraft time
24,321 hours
Engine
Ge CF343A
Part
Switch
Part number
6732127240
Condition
Malfunctioned
Location
Overheat
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING A MAINTENANCE INSPECTION OF THE AIR CONDITION OVERHEAT SWICHES ON BOTH ACU FAIL THE TEST, FOUND INOPERATIVE, DURING THE FUNCTIONAL TEST AS REQUIRED BY THE MM PSP 601-2 , CHAP 21-51-3, P201, THIS CHECK IS REQUIRED AT EVERY 4800 HRS MCN 05-0000-04800. THERE IS NO POSSIBILITY OF TESTING THIS SYSTEM OTHER THAN THAT TEST THOSES PARTS ARE ON CONDITION.