What was found
(CAN) THE FLIGHT CREW WAS ON BOARD THE ACFT FOR GROUND TRAINING, OPERATING PROCEDURES AND COCKPIT FAMILIARIZATION. DURING TESTING OF THE WATER SYS, AFTER THE OPENING OF THE WATER DOORS WITH THE DROP SWITCH, THE LT WATER DOOR FAILED TO CLOSE PROPERLY TO COMPLETE THE NORMAL CYCLE. DURING TROUBLESHOOTING, THE MAINTENANCE CREW FOUND A BROKEN LT INBD UPLOCK LINK. THE LINK LUGS BROKE APART NEAR THE CENTER PIVOT POINT. THE CAUSE OF THAT BREAKAGE IS ACTUALLY UNKNOWN. THE DEFECTIVE PART HAS BEEN REPLACED AND THE SYS WAS SATISFACTORY TESTED. A C-CHECK HAS BEEN CARRIED OUT ON THIS ACFT PRIOR TO THIS INCIDENT. THE COMPLETE WATER SYSTEM HAS BEEN DISMANTLED, INSPECTED, REPAIRED, AND REASSEMBLED. THE LINK ITSELF IS AN "ON CONDITION" PART. ACCORDING TO THE AMM, NO NDT IS REQUIRED TO BE PERFORMED ON THIS PART DURING MAJOR INSPECTION. PART TSO: NOT APPLICABLE, "ON CONDITION". ASSEMBLY, PN 215-26005-882.