Service difficulty report · Flap System · Cndair CL6002B19

Difficulty date
May 5, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Cndair CL6002B19
Part
Flap System
Condition
Out Of Rig
Stage of operation
CL
How discovered
O
Nature of condition
F
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ACFT HAD JUST TAKEN OFF, WHEN THE PILOTS REALIZED WHEN THE FLAPS THAT THEY HAD MECHANICAL PROBLEMS. THEY THEN STOPPED THEIR ASCENT AND OVER THE AIRPORT FOR 45 MINUTES TO CONSUME FUEL. FLAP FAIL CAUTION MESSAGE AFTER RETRACTING THE FLAPS FROM FLAPS 20 DEGREES, FLAPS INDICATE 12 DEG. FOUND BPSUS OUT OF RIG. RIGGED BPSUS AND OPS CHECKED GOOD AT THIS TIME. PERFORMED OPS TEST OF THE FECU, PERFORMED SELF TEST OF THE BPSU BRAKE HOLDING. ALL OPS CHECK GOOD AT THIS TIME.