What was found
(CAN) DURING A HEAVY MAINTENANCE VISIT AND ACCOMPLISHMENT OF TASK DH4-000-79-900-100, OPS CHECK OF THE OIL SYS CHIP DETECTOR CIRCUIT FOR CONTINUITY, CAT 3 FERROUS MATERIAL WAS FOUND ON THE NR 1 AC GEN CHIP DETECTOR. THE GENERATOR WAS REPLACED IAW THE AMM AND OTHER REQUIRED INSPECTIONS WERE COMPLETED. THE GENERATOR HAS BEEN SENT TO THE REPAIR VENDOR. THERE WAS NO ASSOCIATED DEFECT HISTORY IN THE 30 DAYS PRIOR TO THE EVENT. PN 1152218-6, SN 1152218-00737, AC HOURS: 5435, AC CYCLES 4585.