What was found
(CAN) LEFT AILERON TRIM ON TRIM IND .1250 RUDDER TRIM REQUIRED TO FLY S+L FUEL BALANCED. DURING TROUBLESHOOTING FOUND BOTH LT & RT INBD FLAP TRACKS NR 1 LOWER FLAP RODS BROKEN IN HALF. ALSO, BOTH LT AND RT INBD FLAP TRACKS NR 2 FWD RODS BENT. REF IPC 57-54-00-01, FIG 01, SHEET 1 AND SHEET 5. PN 190-92385-901, LT & RT BROKEN AND, PN 190-92387-901, LT & RT BENT. LT AND RT INBD AFT FLAP CONTROL RODS FOUND BROKEN . RODS REPLACED IAW AMM 57-54-30, PB401. FLAP SYSTEM FUNCTION CHECKED IAW AMM 27-50-00-710-80-1A. NO FAULTS.