Service difficulty report · Unknown · Emb ERJ190100IGW

Difficulty date
June 15, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
23,230 hours
Engine
Ge CF3410E5A1
Part
Unknown
Condition
Odor
Location
Cabin
Stage of operation
NR
How discovered
9
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING TAKEOFF ROLL AND INITIAL CLIMB VERY STRONG "DIRTY SOCK" ODOR NOTED BY ALL CREW. ODOR EVENTUALLY DISSIPATED BUT RETURNED ON DESCENT THROUGH 10,000 FT UNTIL LANDING. POSSIBLE CAUSE OF HYD ODOR WAS DUE TO ENGINE EDP. REPLACEMENT, L4624347. CLEANED HYD RESIDUAL FLUID FROM NR 1 ENG EDP. ON FIRST ENG RUN, ODOR REDUCED SIGNIFICANTLY TO NONE. ON 2ND ENGINE RUN , NO ODOR. SYS TESTED SERVICEABLE IAW FIM 21-20-00-810-803-A.