Service difficulty report · Fuel Control · Aerosp ATR42500

Difficulty date
August 30, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Aerosp ATR42500
Engine
Pwc PW127E
Part
Fuel Control
Condition
Malfunctioned
Location
Rt Engine
Stage of operation
TO
How discovered
O
Nature of condition
X, J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) JUST AFTER TAKEOFF, THE CREW REPORTED THE RT SIDE ENGINE FLAMEOUT. THE ACFT LANDED SAFELY AT AIRPORT OF ORIGIN. DURING THE TROUBLESHOOTING, ENGINE DRIVEN FUEL PUMP AND THE HYDRO MECHANICAL UNIT, HMU, WERE REPLACED AND ALL TESTS CARRIED OUT SATISFACTORY. AIRCRAFT HAS BEEN RETURNED TO SERVICE BASED ON CUSTOMER REPORT.