Service difficulty report · Connector · Boeing 7377CT

Difficulty date
September 5, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Boeing 7377CT
Aircraft time
40,281 hours
Engine
Ge CFM567B24
Part
Connector
Part number
BACC63CS16G24P7
Condition
Shorted
Location
Engine
Part time
42,790 hours
Stage of operation
TX
How discovered
O
Nature of condition
H
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CREW REPORTED THEY COULD NOT START NR 1 ENGINE. THEY HAD FUEL FLOW BUT NO EGT. ACFT RETURN TO GATE. MAINTENANCE FOUND NR 1 ENGINE ELECTRONIC ENGINE CONTROL CHANNEL A ALT POWER BREAKER POPPED AND WILL NOT RESET WHEN ELECTRONIC ENGINE CONTROL POWERED, ADDITIONALLY NR 1 ENGINE LT IGN BREAKER ALSO OUT. ALSO, FOUND NR 1 CTAI VALVE NOT INDICATING CORRECTLY. CB WAS OUT AS WELL IT DID RESET OK, BUT STILL NOT INDICATING NORMALLY. COMMON COMPONENT FOR ALL 3 DEFECTS ARE PYLON DISCONNECT D8056. CONNECTOR INSPECTED AND FOUND ARCING DAMAGE TO PIN 21, 22 AND 23. CONNECTOR D08056 P AND J REPLACED ALL AFFECTED SYSTEM, TESTED SERVICEABLE,