Service difficulty report · Circuit Breaker · Boeing 727281

Difficulty date
September 18, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Boeing 727281
Aircraft time
48,762 hours
Engine
Pwa JT8D17
Part
Circuit Breaker
Part number
675231140
Condition
Failed
Location
Hyd System
Stage of operation
NR
How discovered
9
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING TAXI, THE FLT CREW REPORTED THEY HAD NO HYDRAULIC PRESSURE FROM THE NR 1 HYDRAULIC B PUMP AND RETURNED TO THE RAMP. DURING MAINTENANCE TROUBLESHOOTING, THEY FOUND A SYS 40 AMP CIRCUIT BREAKER TRIPPED WITH SIGNS OF BEING BURNED. THE FAULTY BREAKER WAS REPLACED AND ACFT WAS RETURNED TO SERVICE WITHOUT FURTHER INCIDENT.