Difficulty date
November 4, 2014
Submitted
March 12, 2015
Operation
General aviation
Make and model
Diamon DA20C1
Aircraft time
6,527 hours
Part
Gasket
Part number
226053
Condition
Destroyed
Location
Gasket
Part time
533 hours
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING REPLACEMENT OF THE FUEL SENDER IT WAS NOTICED THAT THE NEOPRENE GASKET FOR THE SENDER HAD DISINTEGRATED INTO SEVERAL PIECES AND IT APPEARS AS THOUGH IT HAD BEEN ATTACKED BY A CHEMICAL. THE GASKET WAS ONLY INSTALLED FOR 500 HOURS. THE DIAMOND MAINTENANCE MANUAL GIVES INSTRUCTIONS RELATING TO THE OLD CORK GASKET THAT USED TO BE INSTALLED. IT REQUIRES THAT THE CORK GASKET BE INSTALLED WITH "SEALUBE" SEALANT ON THE GASKET AND SCREWS. THERE IS NO NOTE IN THE MANUAL STATING THAT THIS SHOULD NOT BE ADDED TO THE NEOPRENE GASKET. IF YOU PUT SEALUBE ON THE NEOPRENE IT CAUSES THE GASKET TO SQUEEZE OUT WHEN TRYING TO TORQUE THE ATTACHING SCREWS. EVEN WITH A DRY GASKET THE TORQUE REPORTED IN THE DIAMOND MAINTENANCE MANUAL IS TOO HIGH AND CAUSES A DEFORMATION OF THE GASKET. A FACTORY REP WAS CONSULTED AND STATED THAT THE TORQUE FOR THE NEOPRENE SHOULD BE ABOUT HALF OF THE OLD CORK GASKET. IT IS THE THOUGHT OF THE SUBMITTER THAT THE REASON FOR THE COMPLETE DISINTEGRATION OF THE GASKET MAY HAVE BEEN THE USE OF A CHEMICAL TO CLEAN THE SENDER UNIT AREA AFTER INSTALLATION. WE ARE NOT SURE IF THE SEALUBE ITSELF WOULD DAMAGE THE NEOPRENE GASKET.