(CAN) EDP FAILED DURING FLIGHT AFTER 15 MINS OF TAKEOFF. EDP WAS FOUND OVERHEATED, THE EDP & BOTH SENSE TAPE TEMP STRIP COMPLETELY BLACK FOUND. RESERVOIR WAS FOUND EMPTY. EDP WAS LEAKING AFTER FAILURE AND WAS NOT PRODUCING PRESSURE. EDP REPLACED, ACFT RETURNED TO SERVICE.