Service difficulty report · Stator

Difficulty date
February 28, 2015
Submitted
August 5, 2015
Operation
General aviation
Part
Stator
Part number
23046311
Condition
Wrong Part
Location
Stater Gen
Component
Starter Gen · 250SG117Q
Stage of operation
FF
How discovered
O
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THIS SDR IS TO REPORT AN UNAPPROVED PART THAT WAS INSTALLED ON A STARTER GENERATOR THAT FAILED IN FLIGHT. THE STARTER GENERATOR FAILED IN FLIGHT ON THE LT ENG & WAS REMOVED ON 28 FEB 2015. DETAILS OF THE EVENT WILL HAVE TO COME FROM THE OPERATOR. THE REMOVAL TAG NOTED IT SHORTED INTERNALLY. A TEARDOWN INSPECTION WAS DONE, THE ELEC FAILURE IS EVIDENCED BY TWO COMMUTER BARS 180 ½ APART MELTED AWAY & MELTED & OPEN COPPER PINS AT THE OPPOSITE DRIVE END OF THE ARMATURE. COPPER SPLATTER WAS FOUND ON THE BRUSH HOLDERS & INSIDE THE STATOR HOUSING AT THE DRIVE END. THERE WAS NO FAILURE OF THE BEARINGS. ON EXAMINATION OF THE PARTS, A STATOR HOUSING FROM ANOTHER MANUFACTURER WAS FOUND INSTALLED. THE STARTER GENERATOR, APC MODEL 250SG117Q WAS ASSEMBLED WITH A STATOR ASSEMBLY THAT WAS STAMPED PN 23046-311. THE CORRECT STATOR FOR THIS UNIT IS PN 250SG1156. PARTS ARE PRESENTLY QUARANTINED.