Service difficulty report · Shunt · Bombdr CL6002D15

Difficulty date
May 30, 2015
Submitted
August 5, 2015
Operation
General aviation
Make and model
Bombdr CL6002D15
Aircraft time
29,684 hours
Engine
Ge CF348C5
Part
Shunt
Part number
P700A154E002
Condition
Misinstalled
Location
Main Battery
Part time
30,673 hours
Stage of operation
TX
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) MAIN BATTERY CB FOUND POPPED ON TAXI INTO GATE, NO EICAS MSGS, 1D1 MAIN BATTERY INOPERATIVE. WHILE MX WAS REPLACING SSPC K100 & PERFORMING THE OPERATIONS CHECK THEY FOUND NO CURRENT INDICATION FOR MAIN BATTERY. FOUND SHUNT SENSE WIRES, PN 8406-100, PREVIOUSLY INSTALLED INCORRECT. ONCE SHUNT SH1 SENSE WIRES WERE SWAPPED TO THE CORRECT ORDER, THE CURRENT INDICATION RETURNED & SSPC CHECKED SERVICEABLE. NOTED THERE WAS NO MARKINGS ON THE SHUNTS AS TO (-) OR (+) CONNECTIONS. THIS INCORRECT ASSEMBLY COULD HAVE EASILY BEEN DONE AT THE FACTORY.