Service difficulty report · Handle · Bombdr DHC8400

Difficulty date
June 28, 2015
Submitted
April 22, 2016
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Part
Handle
Condition
Unsecure
Location
Pax Door
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FUSELAGE DOORS WARNING LIGHT ON DURING CLIMB. MFD SHOWED AFT PAX DOOR AFFECTED. HANDLE WAS FOUND SLIGHTLY OUT OF POSITION BY CABIN CREW. PRESSURIZATION INDICATION WAS NORMAL BUT ACCORDING TO QRH AN NORMAL, UNEVENTFUL RELANDING WAS PERFORMED. WARNING LIGHT WENT OUT AGAIN, WHEN DIFF. PRESS DROPPED BELOW 3,5 PSI DURING DESCENT. TROUBLE SHOOTING WAS PERFORMED AND PSEU WAS INTERROGATED. ALL DOOR SENSORS WERE WITHIN ACCEPTABLE RANGE OF MH VALUES PER AMM. EXTERNAL HANDLE WAS OBSERVED POPPED OUT. HANDLE WAS RESET AND AIRCRAFT RELEASED FOR NORMAL FLYING. AIRCRAFT OPERATING SATISFACTORILY SINCE THEN.