What was found
(CAN) NORMAL TAKE OFF, HDG 100, CLIMBING TO 7000 FT. DURING SECOND STAGE CLIMB, WITH CLIMB THRUST SET, PASSING 6000 FT, THE CAPTAIN REPORTED A LOUD BANG ACCOMPANIED BY A YAW TO THE RIGHT. THIS WAS FOLLOWED BY A TRIPLE CHIME, ENG OIL PRESSURE WARNING, AND ITT SPIKED IN THE RED. THAT WAS FOLLOWED BY A RT ENG FLAME OUT WARNING. N1 & N2 THEN BEGAN TO DECELERATE. THERE WAS NO INDICATION OF FIRE. DECLARED EMERGENCY.