What was found
(CAN) UPON ARRIVAL, THE CREW WERE UNABLE TO OPEN THE FWD PASSENGER ENTRY DOOR DESPITE SEVERAL ATTEMPTS FROM INSIDE AND OUTSIDE. PASSENGERS WERE DEPLANED USING THE REAR DOOR AND SUITABLE STEPS. INSPECTION OF THE ACFT FOUND THAT PRESENCE OF SILICA GEL IN THE ELECTRO-PNEUMATIC SHUTOFF VALVE HAD PREVENTED VALVE OPENING AND RELEASING THE SEAL PRESSURE. THIS VALVE IS ELECTRICALLY OPENED BELOW 90 KTS TO ENABLE DOOR SEAL TO DEFLATE. SOURCE OF THE SILICA GEL IS AN UPSTREAM DESICCANT-FILLED FILTER. THE ELECTRO-PNEUMATIC SHUTOFF VALVE WAS CLEANED AND CHECKED. THE MECHANICAL INFLATION/DEFLATION VALVE AND THE DOOR SEAL WERE REPLACED. DOOR FUNCTION WAS CHECKED OK. FOLLOW-UP INVESTIGATION IN CNS REVEALED FAILURE OF DESICCANT FILTER, RESULTING IN LEAKAGE OF DESICCANT GEL INTO DOOR SEAL PRESSURIZATION SYSTEM. FILTER WAS REPLACED AND PRESSURIZATION LINES PURGED. PN OF THE FAILED FILTER IS 8SC5028-001, OR PN F-GGCS. THE IN-LINE DESICCANT FILTER WAS INTRODUCED AT PRODUCTION IAW SB 84-52-71. THESE FILTERS HAVE BEEN FOUND TO BE PRONE TO LEAKING DESICCANT. AN IMPROVED FILTER, PN 8SC5028-003 WAS INTRODUCED IAW SB 84-52-83. NOW HOLDS ONLY THE IMPROVED FILTER TYPE.