Service difficulty report · Insulation · Bombdr DHC8400

Difficulty date
February 5, 2015
Submitted
April 22, 2016
Operation
General aviation
Make and model
Bombdr DHC8400
Engine
Pwc PW150A
Part
Insulation
Condition
Iced
Location
Pax Door
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AFTER LANDING, THE PASSENGER DOOR COULD NOT BE OPENED. AFTER SOME TIME OF DEFROST, IT WAS POSSIBLE TO OPEN (POP OUT) THE HANDLE BUT IT WAS STILL DIFFICULT TO ROTATE THE HANDLE TO OPEN THE DOORS. DURING T/S FOUND THAT BOTH DOORS INSULATION (AFT PAX & SERVICE DOORS) WAS HEAVILY CONTAMINATED WITH ICE AND IT WAS IMPOSSIBLE TO EXTEND THE HANDLE (POP OUT). IT WAS CLEAR THAT INSULATION BLANKET INSIDE DOOR HAS FROZEN AND SO DID THE MECHANISM FOR THE VENT DOOR, MAKING IT DIFFICULT TO OPEN THE HANDLE FROM ITS LOCKED POSITION. AIRCRAFT WAS DEFROSTED IN HANGAR FOR 3 HOURS AND I COULD WITNESS A LARGE AMOUNT OF WATER COMING OUT FROM THE BOTTOM OF THE DOOR. AIRLINE IS CONSIDERING TO REMOVE THE BLANKETS PER IS MODS IS4Q5200022, HOWEVER THEY REALIZE THAT THEY NEED TO RE-INSTALL THESE INSULATION BLANKETS BY 600FH WHICH IS TIME CONSUMING. THEY DID INSPECT THE FLEET AND REALIZE AS WELL THAT THE ISSUE OF WATER CONTAMINATION IS STILL PERSISTING ON THEIR FLEET. IN OTHER WORDS, THIS AIRCRAFT WHICH JUST CAME BACK FROM C-CHECK AT BEGINNING OF JAN, 2015 HAS THE AFT DOORS INSULATION BLANKETS SOAKED WITH WATER ALREADY. ACCUMULATED WATER FREEZES DURING THE FLIGHT AND PREVENTS NORMAL DOOR OPENING, AS THE DOOR HANDLE MECHANISM IS FROZEN AND JAMMED.