Service difficulty report · Sensor · Bombdr BD1001A10

Difficulty date
December 26, 2015
Submitted
April 22, 2016
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Sensor
Part number
190GC03Y02
Condition
Failed
Location
Lt Generator
Stage of operation
CL
How discovered
O
Nature of condition
H, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LEFT GENERATOR FAILED ON TAKEOFF, APU STARTED IN FLIGHT AND RT GENERATOR FAILED AFTER. CREW DID NOT ATTEMPT TO RESTART THE GENERATOR ONCE ON GROUND, REBOOTED PLANE AND LT GENERATOR CAME ON LINE NORMALLY. THE RIGHT WOULD NOT AND SHOWS ZERO VOLTS WITH AMBER, RT GEN FAIL). DIFF PROT SENSOR 1 FAIL, POSTED IN THE MDC. R & R THE DPMS1 IN THE LDCPC AND REPLACED THE RT GENERATOR, SHAFT SHEARED. OPS CHECKS SATISFACTORY.