Service difficulty report · Oxygen System · Cndair CL6002C10

Difficulty date
January 11, 2016
Submitted
June 13, 2017
Operation
General aviation
Make and model
Cndair CL6002C10
Part
Oxygen System
Condition
Contaminated
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) THE CREW OXYGEN DISTRIBUTION TUBING HAS BEEN FOUND IN PRODUCTION TO CONTAIN KRYTOX (PTFE (20-30%) PERFLUOROPOLYETHER (70-80%)) IN THE FITTINGS. THE CREW OXYGEN DISTRIBUTION SYSTEM SHALL BE DESIGNED TO BE CLEAR OF CONTAMINATES. THIS CONDITION EXISTS ON 100 AIRCRAFTS (CRJ700/900/1000). BOMBARDIER HAS A CONTINUING AIRWORTHINESS PROJECT OPEN FOR THIS ISSUE (RJX-CA-35-17) ++X++ (TC# 20160113004)