Service difficulty report · Wire · Bombdr BD1001A10

Difficulty date
February 4, 2016
Submitted
April 22, 2016
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Wire
Condition
Burned
Location
Compass
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AN OVERHEATING CONDITION THAT RESULTED IN FLAME IGNITION, OCCURRED WITHIN THE ELECTRICAL LEAD AND SOCKET ASSY CE2-A26 INSTALLED ON A CIVIL ACFT. THE LEAD ASSY IS SUPPLIED WITH A RANGE OF MAGNETIC STANDBY COMPASSES INCLUDING TYPE WL1001KCA1 SUPPLIED TO YOUR ORGANISATION. AN INVESTIGATION AT SIRS HAS IDENTIFIED THAT ELECTRICAL LEADS MFG BETWEEN 3RD QUARTER 2005 AND SEPTEMBER 2012 COULD ALSO HAVE A RISK OF IGNITION. DURING NORMAL FLIGHT OPERATIONS, IT WAS DETECTED ON 2 DIFFERENT TYPES OF ACFT THAT THE LEAD AND SOCKET ASSEMBLIES FEEDING THE STANDBY COMPASS LIGHTING PRODUCED FUMES, AND IN 1 CASE SMALL FLAMES. THE ROOT CAUSE OF THIS PHENOMENON IS STILL UNDETERMINED AND TEST DATA ARE STILL MISSING TO CONFIRM OR NOT THE UNSAFE CONDITION. HOWEVER, INVESTIGATION REVEALED THAT A BATCH OF 216 LEAD ASSEMBLIES MFG IN JULY 2011 CONTAIN BOGUS MATERIAL, WHICH IS CONSIDERED TO BE 1 OF THE MAIN CONTRIBUTORS TO THESE INCIDENTS. AFTER PERFORMING A DETAILED RESEARCH, THE EQUIPMENT MFG COULD NOT IDENTIFY ALL DELIVERIES CONTAINING DEFECTIVE LEAD ASSEMBLIES.