Service difficulty report · Wire · Aerosp ATR42300

Difficulty date
July 22, 2018
Submitted
August 18, 2020
Operation
General aviation
Make and model
Aerosp ATR42300
Aircraft time
37,813 hours
Engine
Pwa PW120
Propeller
Hamstd 14SF5
Part
Wire
Condition
Chafed
Location
Nr 2 Fms
Stage of operation
TO
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ELEC SMOKE ON TAKE OFF BY CAPT LEFT KNEE. FOUND 2 FMS WIRES W09008-815 & W09008-816 CHAFED, BOTH WIRES ISOLATED & SECURED. ALL OTHER LOCAL WIRING INSPECTED. NO FURTHER DAMAGED FOUND NR 2 FMS INOPERABLE, DMI 55164 OPENED, IAW MEL 34-60-1A. INOPERABLE STICKER AFIXED, TWO C/B COLLARED. ENGINE RUNS CARRIED OUT, AS PER JIC 72-00-00 OPT 10000. (TC# 20180723019)