Service difficulty report · Circuit Card · Bombdr BD1001A10

Difficulty date
February 4, 2019
Submitted
August 14, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Engine
Hnywl AS90711A
Part
Circuit Card
Part number
355CE03Y06
Condition
Faulted
Location
Left
Stage of operation
IN
How discovered
9
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON THE GROUND WITH APU GEN ON-LINE - CYAN ICAS (ELECTRICAL FAULT) ALONG WITH A WHITE (APU GEN OFF) + (L BATT OFF) AND (R BATT OFF) THE PBA OFF LIGHTS WERE CYCLING ON AND OFF ALSO. THE LEFT BATTERY BOX WOULD FLASH YELLOW ALONG WITH THE FLOW TUBES WOULD GO WHITE ALONG WITH THE APU GENERATORS. BATTERY VOLTAGE STAYED AT 28.5 VDC AND APU GENERATOR VOLTAGE STAYED AT 28.5 VDC/120 AMPS. FEB 5/2019: REMOVED & CLEANED LEFT PROTECTION CARD (PCB1) WITH CONTACT CLEANER. INSPECTED CONTACTS/SOCKETS WITH NO DEFECT NOTED. POWERED AC WITH NO DEFECT. AC RTS`D. (TC# 20190226008)