Service difficulty report · Bleed Valve · Emb ERJ190100IGW

Difficulty date
March 1, 2019
Submitted
August 14, 2020
Operation
General aviation
Make and model
Emb ERJ190100IGW
Aircraft time
34,077 hours
Engine
Ge CF3410E5A1
Part
Bleed Valve
Part number
10139521
Condition
Failed
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LEFT WITH ONE BLEED AIR SYSTEM UNDER MEL. ENROUTE, THE OTHER BLEED AIR SYSTEM FAILED. MTC SUGGESTED THAT THE AIRCRAFT SHOULD RETURN RESOLUTION REPLACED NAPRSOV AS PER AMM 36-11-03-000-801-A ON LEAK CHK FOUND LOWER SEALS LEAKING INSTALLED NEW SEALS. REPLACED HPSOV IAW AMM 36-11-01-000-801-A AND 36-11-01-400-801-A. OPS CHK SERV. LEAK CHK BOTH HPSOV AND NAPSOV CARRIED OUT NFF.