Service difficulty report · O-Ring · Bombdr DHC8400

Difficulty date
March 19, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr DHC8400
Part
O-Ring
Part number
NAS1612
Condition
Leaking
Location
Hyd System
Stage of operation
DE
How discovered
O
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON APPROACH, CREW OBSERVED NO. 2 HYDRAULIC SYSTEM QUANTITY DROPPED TO ZERO. AIRCRAFT LANDED AT DESTINATION AIRPORT. WHILE ON APPROACH ON LOCALIZER AFTER FLAPS WAS LOWERED TO 5 DEG AND U/L WAS LOWERED. NO. 2 HYD ISOL VLV LIGHT ALONG WITH SPOILER O/B AND ROLL SPOILER O/B HYD CAUTION CAME ON. QTY DROPPED TO ZERO WITH PRESSURE INDICATED AT 3000 PSI.