As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(CAN) CORROSION WASTE ACCESS PANEL SURROUND DURING ROUTINE MAINTENANCE, CORROSION WAS FOUND ON THE WASTE ACCESS PANEL SURROUND OF MSN: 50017 (HB-JBH). THE CORROSION WAS BLENDED. HFEC INSPECTION CONFIRMED THAT ALL CORROSION IS REMOVED. THE MINIMUM REMAINING THICKNESS IS 2.56MM. PLEASE REFER TO NDT19-136.PDF FOR THE DETAILS. REO-500-53-61-035_- PROVIDED (TC# 20190422008)