Service difficulty report · Pump · Bombdr BD1001A10

Difficulty date
April 24, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Pump
Part number
ML60A3
Condition
Failed
Location
Hyd System
Part time
5,580 hours
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found