Service difficulty report · Shutoff Valve · Cessna 172P

Difficulty date
April 25, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Cessna 172P
Aircraft time
15,647 hours
Engine
Lyc O320D2J
Part
Shutoff Valve
Part number
O320D2J
Condition
Contaminated
Location
Fuel System
Stage of operation
TO
How discovered
O
Nature of condition
R, Y
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON A TRAINING FLIGHT IT WAS REPORTED THAT ON THE TAKE-OFF ROLL THE ENGINE QUIT AND THE AIRCRAFT WAS ABLE TO COAST OFF THE RUNWAY TO A TAXIWAY. THE AIRCRAFT WAS RE-STARTED AND TAXIED BACK TO THE HANGAR. MAINTENANCE DID A THOROUGH RUN-UP ON THE AIRCRAFT AND COULD NOT FIND ANYTHING ABNORMAL ABOUT ITS OPERATION AND COULD NOT DUPLICATE THE REPORTED DEFECT. AIRCRAFT WAS BROUGHT INTO MAINTENANCE FOR INSPECTION OF RELATED SYSTEMS, FUEL AND SCREENS CHECKED FOR CONTAMINATION, NFF. ENGINE CYLINDER COMPRESSIONS, MAGNETO TIMING, SPARK PLUGS, INDUCTION SYSTEM, AND AIR FILTER ALL CHECKED OK. A VISUAL INSPECTION OF THE ENGINE SHOWED NO EVIDENCE OF ABNORMALITIES. ANOTHER GROUND RUN WAS CARRIED OUT WITH SATISFACTORY RESULTS. AS A TEST, ANOTHER RUN UP WAS CARRIED OUT WITH THE FUEL SELECTOR SET JUST OUT OF THE DETENT OF THE `BOTH` POSITION CAUSING THE FUEL VALVE TO NOT BE FULLY OPEN, YET STILL HAVING THE POINTER RELATIVELY CLOSE TO THE `BOTH` PLACARD. A SUCCESSFUL RUN-UP WAS CARRIED OUT WITH THIS SETTING AT 1700 RPM BUT WHEN FULL POWER WAS SELECTED THE ENGINE WOULD ONLY RUN FOR APPROX. 20 SECONDS BEFORE IT WOULD QUIT FROM FUEL STARVATION. IT IS SUSPECTED THE FUEL SELECTOR WAS NOT FULLY ENGAGED IN THE DETENT PRIOR TO ATTEMPTED TAKE-OFF CAUSING INADEQUATE FUEL DELIVERY AT FULL POWER SETTINGS. (TC# 20190429020)

More about the Cessna 172P