Service difficulty report · Pseu · Bombdr DHC8400

Difficulty date
May 21, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr DHC8400
Aircraft time
23,503 hours
Part
Pseu
Part number
301450601
Condition
Unserviceable
Location
Nlg
Part time
7,577 hours
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) NOSE GEAR UNSAFE INDICATION WHEN GEAR SELECTED DOWN, ALTERNATE EXTENSION SATISFACTORY. PSEU FLT LEG 00 FAULT CODES RETRIEVED. (NGDRCL UNRSNABL NEAR, NGDN2 UNRSNABL FAR, NGLK2 UNRSNABL FAR, NGDN1 UNRSNABL FAR, NGLK1 UNRSNABL FAR, LGDRCL UNRSNABL FAR, NGDRCL UNRSNABL FAR, RGDRCL UNRSNABL FAR, NGWOFW1 UNRSNABL NEAR, NGWOFW2 UNRSNABL NEAR). ALL NLG PROX SENSOR INDUCTANCES CHECKED SERVICEABLE PER AMM 32-61-00-280-801. FOUND NLG DOOR SSV FAILED FUNCTION TEST PER SUBTASK 32-31-71-710-002. NLG DOOR SSV REPLACED IAW AMM 32-31-71-000/400-801. NLG GEAR SWINGS COMPLETED REPEATEDLY WITH NO FAULTS NOTED. WITH BOTH HYD SYSTEMS PRESSURIZED, FOUND THAT SELECTING LG INHIBIT SWITCH TO INHIBIT WOULD INTERMITTENTLY NOT OPEN NLG DOORS (MLG DOORS OPENED UPON EVERY SELECTION TO INHIBIT). SUGGEST REPLACING PSEU. PSEU REPLACED AND TESTED SERVICEABLE AS PER AMM 32-61-01-400-801. GEAR SWINGS TO BE CARRIED OUT. GEAR SWINGS COMPLETED WITH REFERENCE TO AMM 32-334-00-710-802 AND 32-34-00-710-801 AT BOTH 6 GPM AND 22 GPM SUPPLIED FROM THE GPU, WITH NO FAULTS FOUND. GEAR SWUNG IN CORRECT SEQUENCE AND WITHIN THE TIME FRAME NOTED IN THE AMM. SERVICEABLE FOR FURTHER FLIGHT. NOTE 2776 HRS TSR ON REMOVED PSEU (TC# 20190522012)