What was found
(CAN) THE FBW SUPPLIER HAS IDENTIFIED A LACK OF MONITOR COVERAGE TO ADDRESS FAILURE MODES ON THE EHSV LVT SENSOR. AS SUCH, WITH THE CURRENT FBW SYSTEM, THE EHSV POSITION SENSING PATH (LVT) CAN FAIL IN A MANNER THAT IS NOT DETECTABLE (DORMANT). THIS EHSV LVT SENSOR IS USED TO SENSE THE EHSV POSITION TO MONITOR FOR EHSV HARD OVER, JAM OR EHSV FEEDBACK SPRING FAILURES OF THE PRIMARY PCUS (IE: AILERON, ELEVATOR, RUDDER ACTUATORS).