(CAN) FLAP POWER LIGHT AFTER TAKE OFF WITH FLAPS STUCK AT APPROXIMATELY 4 DEGREES. FLIGHT CONTINUED TO DESTINATION AIRPORT AND FLAP CONTROL UNIT REPLACED IAW AMM 27-51-01-000-801 AND 27-51-01-400-801. FUNCTIONAL TEST OF FLAP CONTROL SYSTEM CARRIED OUT SERVICEABLE IAW AMM 27-51-00-720-801. (TC# 20190626003)