Service difficulty report · Power Supply · Bombdr DHC8400

Difficulty date
June 20, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr DHC8400
Part
Power Supply
Part number
50251
Condition
Failed
Location
Emergency Lights
Stage of operation
AP
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) LIGHT SMELL OBSERVED IN THE COCKPIT AFTER ENTRANCE. EMERG LIGHTS ON, A/C POWER OFF. TO PREVENT EMPTY EMERG BATTERY PACKS, A/C POWER SWITCHED ON AND EMERG TOGGLE SW TURNED TO OFF BUT EMERG LIGHTS STILL ON. C/B CHECKED AT L/H ELECTR PANEL, FOUT EMER LTS (G3) C/B POPPED. PUSHED IN AND NOW IT IS POSSIBLE TO SWITCH OFF EMERG LIGHTS. EMERG LIGHTS SWITCHED ON AGAIN BUT EMERG LIGHTS STAYED OFF AND C/B G3 POPPED AGAIN. POSSIBLE CAUSE: C/B G3 POPPED EVERY TIME IF YOU SWITCH ON THE EMERG LIGHTS. AFTER FEW MINUTES AGAIN LIGHT ELECTRICAL SMELL (TC# 20190705007)