Service difficulty report · Circuit Card · Bombdr BD1001A10

Difficulty date
July 8, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Circuit Card
Part number
355CE03Y06
Condition
Failed
Location
Dc Power
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING PRE-FLIGHT CHECK, L/H HYD DC MOTOR PUMP IS RUNNING ALL THE TIME ON GROUND IN THE `AUTO` POSITION. AIRCRAFT CONFIGURATION: WOW, APU RUNNING (APU GEN `ON`), BOTH DCMP SELECTED TO `AUTO`, FAPS AT ZERO AND THE L/H DCMP RUNS CONTINUOUSLY. SWAPPED THE L/H & R/H DCPC PROTECTION CARDS & THE PROBLEM FOLLOWED THE CARD. PROTECTION CARD REPLACED. (TC# 20190709003)