Service difficulty report · Control Panel · Bombdr BD1001A10

Difficulty date
June 3, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Control Panel
Part number
SPCTL011
Condition
Burned
Stage of operation
IN
How discovered
O
Nature of condition
B, A
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) WITH POWER APPLIED, VIP CONTROL PANEL STARTED SMOKING WITH FLAMES UNTIL POWER WAS REMOVED. REMOVED AND INSTALLED A CUSTOMER SUPPLIED REPAIRED VIP SWITCH PANEL IAW BD-100 SMM 44-10-15. PERFORMED SATISFACTORY OPERATIONAL TEST OF THE CABIN ENTERTAINMENT SYSTEM PER BD-100 SMM 44-10-00. PN OFF:SP-CTL-01-1 S/N OFF:090400750 PN ON :SP-CTL-01-1 S/N ON: 090400913 (TC# 20190717011)