Service difficulty report · Overheat Loop · Bombdr BD1001A10

Difficulty date
July 19, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Overheat Loop
Condition
Out Of Position
Location
Right
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) ON CLIMB-OUT *RED* R BLEED LEAK CAS POSTED. CREW TURNED AROUND AND DIVERTED BACK TO DEPARTURE AIRPORT. BLEED LEAK LOCATION WAS 54%. MAINTENANCE HAD JUST ACCOMPLISHED SOME WORK ON THE PLANE RECENTLY. FOUND BLEED AIR LEAK ELEMENT (LOOP) TOUCHING RIGHT BLEED VALVE (IPV) BOOT AND ALSO NOTED A LARGE LEAK COMING FROM THE LOWER FLOW CONTROL VALVE (FCV) AND THE LEAK WAS POINTED TOWARDS MT38 LOOP. RE-POSITIONED RIGHT IPV AND MT38 LOOP. (TC# 20190815001)