Service difficulty report · Sensor · Cndair CL600*

Difficulty date
July 19, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Cndair CL600*
Part
Sensor
Part number
GG43620153
Condition
Faulty
Location
Pack Temp
Stage of operation
CL
How discovered
9
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CLIMBING , THE PACKS DO NOT SEEM TO REGULATE IN AUTO ESPECIALLY THE NUMBER 1 WITH ICE COMING OUT CDB SIDE. THEN LOSS OF THE ED 1, PASSAGE IN MANUAL ON THE 1, -18 C IN THE PIPES, MESSAGE STATUS RRARV FAULT, CALLING CABIN, NOISE CONDITIONING IN CAB, THEN LOSS OF ED 2. GROUND RETURN DECISION ON THE RETURN, THE TEMPERATURE INCREASING RECOVERY OF BOTH SCREENS IN THE PARKING AFTER THE PACKS HAVE BEEN CUT, THE SMELL OF BURNING IN FRONT AND BEHIND. CORRECTIVE ACTION: TEMPERATURE SENSOR MT21 (TC# 20191003020)