What was found
(CAN) FOUND CORROSION AT FLOOR BEAM BETWEEN FS605.00 - FS621.00 AND AT LBL27.00. PERFORM BLEND OUT TO SMOOTH SURFACE IAW SRM 51-21-06. (TC# 20191018015)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) FOUND CORROSION AT FLOOR BEAM BETWEEN FS605.00 - FS621.00 AND AT LBL27.00. PERFORM BLEND OUT TO SMOOTH SURFACE IAW SRM 51-21-06. (TC# 20191018015)