What was found
(CAN) OPERATOR REPORTED QTY. 4 (FOUR) AREAS OF BLENDED CORROSION DAMAGE `1`0 FUSELAGE SKIN BETWEEN FS559.00 & FS559.00+96.00 AND STRINGERS 26L & 26R. - BLEND 1: 3.20" L X 2.20" W X MIN. REMAINING THICKNESS OF 0.056" (REF) AT FS559.00+16.00 BETWEEN STRINGERS 26L & 27 (0.058" 0.002" SKIN + 0.050" BONDED DOUBLER). - BLEND 2: 1.60" LX 1.40" W X MIN. REMAINING THICKNESS OF 0.056" (REF) AT FS559.00+64.00 BETWEEN STRINGERS 26L & 26R (0.058" 0.002" SKIN + 0.050" BONDED DOUBLER). - BLEND 3: 2.20" L X 2.00" W X MIN. REMAINING THICKNESS OF 0.056" (REF) AI` FS559.00+96.00 BETWEEN STRINGERS 26L & 27 (0.058" 0.002" SKIN). - BLEND 4: 2.70" L X 2.00" W X MIN. REMAINING THICKNESS OF 0.056" (REF) AT FS559.00+96.00 BETWEEN STRINGERS 27 & 26R (0.058" 0.002" SKIN). (TC# 20191018023)