What was found
(CAN) PRESSURE FLOOR SUPPORT BEAM CORROSION FOUND @ FS409+120 RBL9.0, MIN. REM. MAT. THK. OF .026 IN CENTER OF BLEND. (TC# 20191021045)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) PRESSURE FLOOR SUPPORT BEAM CORROSION FOUND @ FS409+120 RBL9.0, MIN. REM. MAT. THK. OF .026 IN CENTER OF BLEND. (TC# 20191021045)